Summary: an API 650 tank is a vertical, cylindrical, above-ground welded steel storage tank designed and built to API Standard 650, Welded Tanks for Oil Storage, published by the American Petroleum Institute. API 650 applies to tanks at atmospheric pressure or low internal pressure (up to 2.5 psig with Annex F) and design metal temperatures up to 200°F (up to 500°F with Annex M). It is used for crude oil, refined fuels, chemicals and many industrial liquids, and in-service tanks are inspected, repaired and altered under API 653. MMI Tank & Industrial Services designs, fabricates and erects API 650 tanks from Phoenix, Arizona.
What Is API 650?
API 650 is the standard most U.S. owners, engineers and regulators use for welded storage tanks that hold petroleum and other liquids. It sets minimum requirements for:
- Materials: plate, pipe, flanges and bolting
- Design: shell, bottom, roof, nozzles, manholes and wind girders
- Fabrication and erection: tolerances, welding and weld details
- Inspection and testing: weld examination, vacuum box testing of bottom welds and hydrostatic testing
- Marking and documentation: nameplate, certification and records
What Is the Difference Between API 650 and API 653?
| API 650 | API 653 | |
|---|---|---|
| Applies to | New tanks | Existing tanks in service |
| Covers | Design, fabrication, erection, testing | Inspection, repair, alteration, relocation and reconstruction |
| Inspector | Manufacturer’s inspection plus purchaser’s inspector | API-certified 653 authorized inspector |
| Interval | One-time construction | Ongoing; external inspection at least every five years, internal based on corrosion rate |
See MMI’s API 653 tank repair and renovation.
API 650 vs Other Tank Standards
| Standard | Construction | Typical use |
|---|---|---|
| API 650 | Welded, atmospheric to 2.5 psig | Oil, fuel, chemicals, industrial liquids |
| API 620 | Welded, low pressure up to 15 psig | Low-pressure and refrigerated storage |
| API 12F | Shop-welded small tanks | Oil field production liquids |
| API 12B | Bolted | Oil field production liquids |
| AWWA D100 | Welded | Potable water, ground and elevated |
| AWWA D103 | Bolted, factory-coated | Water storage |
| UL 142 | Shop-fabricated | Flammable and combustible liquids, smaller tanks |
Detailed comparison: API 650 vs AWWA D100. For smaller fuel tanks, see UL 142 tanks.
What Are the Main API 650 Annexes?
- Annex A: optional simplified design for smaller tanks.
- Annex C: external floating roofs.
- Annex E: seismic design. Critical in Arizona, California, Nevada and the Pacific Northwest.
- Annex F: design for small internal pressures, up to 2.5 psig.
- Annex H: internal floating roofs.
- Annex J: shop-assembled tanks.
- Annex M: elevated temperature service, up to 500°F.
- Annex S and X: austenitic and duplex stainless steel tanks.
- Annex V: external pressure design.
Annex numbering and limits change between editions; always design to the edition named in the project specification.
How Is an API 650 Tank Built?
- Design: shell thickness by the one-foot or variable-design-point method, bottom and annular plates, roof type (cone, dome, floating), nozzles, wind girders, and Annex E seismic and anchorage.
- Foundation: concrete ringwall or slab sized from a geotechnical report. See tank foundations.
- Fabrication: plates cut, beveled and rolled to radius in the shop.
- Erection: bottom welded and vacuum-box tested, shell courses set and welded, roof installed.
- Examination: radiographic or other approved examination of shell welds.
- Hydrostatic test: the tank is filled with water and checked for leaks and settlement.
- Coating and documentation: interior lining and exterior coating as specified, nameplate and records.
Shop-Built vs Field-Erected API 650 Tanks
Tanks small enough to ship, typically around 12 ft in diameter, can be built and tested in a shop under Annex J and delivered complete. Larger tanks are field-erected. MMI does both: shop tanks at its 8-acre Phoenix plant with plate rolls up to 1-7/8 in. thick, and field-erected tanks on site.
Where Are API 650 Tanks Used?
- Refineries, terminals and fuel storage
- Oil and gas production and midstream. See oil and gas tanks.
- Chemical and process plants
- Mining: process water, leach solution and reagents. See mining tanks.
- Power generation, ethanol and biofuels
- Industrial water, fire water and wastewater when the owner specifies API 650
Frequently Asked Questions
What does API 650 stand for?
API 650 is American Petroleum Institute Standard 650, Welded Tanks for Oil Storage. It is the main U.S. standard for welded above-ground storage tanks.
What pressure is an API 650 tank designed for?
Atmospheric pressure in the basic standard, or small internal pressures up to 2.5 psig under Annex F. Higher pressures up to 15 psig fall under API 620.
Can API 650 tanks store water?
Yes. API 650 tanks are often used for industrial and fire water. Potable water tanks are normally built to AWWA D100 and coated with NSF/ANSI 61 certified linings.
What is the maximum size of an API 650 tank?
API 650 does not set a practical maximum. Tanks range from shop-built units to field-erected tanks hundreds of feet in diameter.
How often must an API 650 tank be inspected?
Under API 653, external inspection by an authorized inspector is required at least every five years, and internal inspection intervals are set from the measured corrosion rate.
Who builds API 650 tanks in Arizona?
MMI Tank & Industrial Services designs, fabricates and erects API 650 tanks from Phoenix, Arizona, and inspects and repairs them under API 653. See API 650 tank construction or request a quote.